"Protection begins with Detection" 

 

 

 

Buy online at Arrow-Tech, Inc's Online Store

DCA Products - Survey Meters, Probes , Area Monitors and Dosimeter Chargers

"Protection begins with Detection"

  Area Alarm Monitors

 Radiation Detected - X-Ray and Gamma (all models)

Models 3096-3, 3090-3 and 3090-HR

                                                        Spec sheet - PDF file                           Instruction Manual - PDF file                                                                                                                             for 3096-3 and 3090-3 models

Model 3096-3 / 3096-3 SV

 

Range (with Internal detector)

 

  • 0.1 mR/h to 2 R/h

  • 0.001 mSv/h to 20 mSv/h

Range of Alarm settings

  • 0.2 mR/h to 2 R/h

  • 0.002 mSv/h to 20.0 mSv/h

Detector Type

Energy Compensated, halogen quenched GM tube (Internal & External)

 

Optional - External Detector

 

Available with 50 ft or 100 ft cables (when external probe is connected the internal detector is disabled)

Probe #  3093-R

Energy Response

Internal and External

±30% 80 keV to 1.22 MeV

Accuracy

Within ± 20% referred to Cs-137 from 0.2 mR/h to 2 R/hr

Speaker

Sonalert>80 dBA @ 2Ft on front Panel

Visual Indicators

Power ON,LED on front panel, red alarm light on top of instrument

Accumulated Dose

GM tube life is Approx. 2,000 Rads

Response time

90% of final reading within 7 seconds

Power

  • AC Power

  • DC Power

 

Operates from AC power and/or optional backup battery pack.  Nominal 4 watts, Fused at 1/8 Amp.  115 VAC ±15%, 60 Hz or 230 VAC ±15%, 50 Hz

+ and – 9 volts connected to appropriate pins of auxiliary connector

 

click image to enlarge

Picture shown with Optional - External Probe

  • Model 3096-3

  • or Model 3096-3 SV

-----------------------------------------------------------------------------------------------------------

 

Model 3090-3 / 3090-3 SV

 

Range (with Internal detector)

 

  • 1 mR/h to 100 R/h

  • 0.01 mSv/h to 1,000 mSv/h

Range of Alarm settings

  • 2.0 mR/h to 100 R/h

  • 0.02 mSv/h to 1,000.0 mSv/h

Detector Type

Energy Compensated, halogen quenched GM tube (Internal & External)

 

Optional - External Detector

 

Available with 50 ft or 100 ft cables (when external probe is connected the internal detector is disabled)

Probe #  3094-R

Energy Response

Internal and External

±30% 80 keV to 1.22 MeV

Accuracy

Within ± 20% referred to Cs-137 from 2 mR/h to 100 R/hr

Speaker

Sonalert>80 dBA @ 2Ft on front Panel

Visual Indicators

Power ON,LED on front panel, red alarm light on top of instrument

Accumulated Dose

GM tube life is Approx. 10 K Rads

Response time

90% of final reading within 7 seconds

Power

  • AC Power

  • DC Power

 

Operates from AC power and/or optional backup battery pack.  Nominal 4 watts, Fused at 1/8 Amp.  115 VAC ±15%, 60 Hz or 230 VAC ±15%, 50 Hz

+ and – 9 volts connected to appropriate pins of auxiliary connector

 

click image to enlarge

Picture shown with Optional - External Probe

  • Model 3090-3

  • or Model 3090-3 SV

 

 

-----------------------------------------------------------------------------------------------------------

Model 3090-HR / 3090- HR Sv

 

Range (with Internal detector)

 

  • 10 mR/h to 1,000 R/h

  • 0.1 mSv/h to 10 Sv/h

Range of Alarm settings

  • 20 mR/h to 1,000 R/h

  • 0.2 mSv/h to 10 Sv/h

Detector Type

Energy Compensated, halogen quenched GM tube (Internal & External)

 

Optional - External Detector

 

Available with 50 ft or 100 ft cables (when external probe is connected the internal detector is disabled)

Probe #  3095-R

Energy Response

Internal and External

±30% 80 keV to 1.22 MeV

Accuracy

Within ± 20% referred to Cs-137 from 0.2 mR/h to 2 R/hr

Speaker

Sonalert>80 dBA @ 2Ft on front Panel

Visual Indicators

Power ON,LED on front panel, red alarm light on top of instrument

Accumulated Dose

GM tube life is Approx. 100 K Rads

Response time

90% of final reading within 7 seconds

Power

  • AC Power

  • DC Power

 

Operates from AC power and/or optional backup battery pack.  Nominal 4 watts, Fused at 1/8 Amp.  115 VAC ±15%, 60 Hz or 230 VAC ±15%, 50 Hz

+ and – 9 volts connected to appropriate pins of auxiliary connector

 

click image to enlarge

Picture shown with Optional - External Probe

  • Model 3090-HR

  • or Model 3090-HR SV

 

 
 

 


Send mail to dleas@arrowtechinc.com    with questions or comments about this site.